Specifications

APC NETSHELTER METERED RACK PD U 0U 8.6KW 208V 3 PHASE 30A 36 C13

48 specifications

Specifications7
ManufacturerDell Technologies
Manufacturer Part NumberA7284149
Manufacturer Website Addresshttp://www.delltechnologies.com
Brand NameDell
Product Name44-Outlets PDU
Marketing Information

Power Distribution

The growing complexity of IT environments, from wiring closets and server rooms to data centers of all sizes, has increased the need for reliable power distribution to the rack level. Eliminating power management issues is essential for IT and Facilities managers to maintain system availability of increasing higher density equipment. Power Distribution Units are an essential element in managing power capacity and functionality for critical network, server and data center equipment.

APC provides a wide array of power distribution solutions for your IT environment. APCs standardized PDUs are designed to increase the manageability and efficiency of your data center. Power Distribution solutions provide real-time remote load monitoring of connected equipment and individual outlet power control for remote power recycling, manage power-up or power-down sequencing of equipment. IT and Data Center Managers rely on APC PDU alarms to warn of potential power overloads before critical IT failures occur.

Features | Metered Rack PDU

Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

Keeping your eye open for unplanned overloads

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency. New AP8000 series Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.

Product TypePDU
Technical Information11
PDU TypeMetered
PhaseThree Phase
Plug/Connector TypeNEMA L21-30P
Plug/Connector Detail1 x NEMA L21-30P
Receptacle Type
  • IEC 60320 C13
  • IEC 60320 C19
  • NEMA 5-20R
Receptacle Detail
  • 36 x IEC 60320 C13
  • 6 x IEC 60320 C19
  • 2 x NEMA 5-20R
Protection TypeOverload Protection
Locking Receptacles
  • IEC 60320 C13
  • IEC 60320 C19
Environmental SensorsTemperature/Humidity
FeaturesLCD Display
Load Capacity (Watt)8600 W
Power Description6
Input Voltage230 V AC
Output Voltage
  • 120 V AC
  • 208 V AC
Power Rating (Watt)8600 W
Input Current30 A
Input Frequency60 Hz
Circuit BreakerYes
Management1
Management
  • SNMP
  • Telnet
  • HTTP
Physical Characteristics11
Color FamilyBlack
Product ColorBlack
Mounting OrientationVertical
Mount TypeRack-mountable
Form FactorVertical
Rack Height0U
Cord Length6 ft
Height70.5"
Width2.2"
Depth1.8"
Weight (Approximate)16.64 lb
Environmental Conditions6
Minimum Operating Temperature23°F (-5°C)
Maximum Operating Temperature113°F (45°C)
Minimum Storage Temperature-13°F (-25°C)
Maximum Storage Temperature149°F (65°C)
Minimum Operating Humidity5%
Maximum Operating Humidity95%
Miscellaneous5
Package Contents
  • 44-Outlets PDU
  • Rack Mounting Kit
Application/Usage
  • IT Equipment
  • Server Rack/Cabinet
Compatibility

Schneider APC Products:

  • AR2200
  • AR2280
  • AR2400
  • AR2400FP1
  • AR2401
  • AR2407
  • AR2480
  • AR2487
  • AR2487G
  • AR2500
  • AR2507
  • AR2580
  • AR2587
  • AR3100G
  • AR3100TAA
  • AR3100W
  • AR3100X609
  • AR3100X610
  • AR3100X617
  • AR3105
  • AR3105SP
  • AR3105W
  • AR3107G
  • AR3107SP
  • AR3107X609
  • AR3107X610
  • AR3107X617
  • AR3140G
  • AR3140W
  • AR3150SP
  • AR3150W
  • AR3150X609
  • AR3150X610
  • AR3150X617
  • AR3155
  • AR3155SP
  • AR3155W
  • AR3157SP
  • AR3157X609
  • AR3157X610
  • AR3157X617
  • AR3180G
  • AR3300G
  • AR3300SP
  • AR3300W
  • AR3300X609
  • AR3300X610
  • AR3300X617
  • AR3305
  • AR3305SP
  • AR3305W
  • AR3307SP
  • AR3307W
  • AR3307X609
  • AR3307X610
  • AR3307X617
  • AR3340G
  • AR3340W
  • AR3350SP
  • AR3350W
  • AR3350X609
  • AR3350X610
  • AR3350X617
  • AR3355
  • AR3355SP
  • AR3355W
  • AR3357SP
  • AR3357X609
  • AR3357X610
  • AR3357X617
  • AR3357X674
  • AR9300SP
  • AR9300SP-R
  • AR9307SP
  • AR9307SP-R
  • NBES0302
  • NBPD0160A
  • NBPD0180SMC1000
  • SMC1000-2U
  • SMC1000-BR
  • SMC1000I
  • SMC1000I-2U
  • SMC1000I-2UC
  • SMC1000I-BR
  • SMC1000IC
  • SMC1500
  • SMC15002U-BR
  • SMC1500-BR
  • SMC1500I
  • SMC1500I-2U
  • SMC1500I2U-BR
  • SMC1500I-2UC
  • SMC1500I-BR
  • SMC1500IC
  • SMC2000I-2U
  • SMC3000RMI2U
  • SMT1500RM1U
  • SMT1500RM2U
  • SMT1500RMI1U
  • SMT2200RM2UC
  • SMT3000I2U-BR
  • SMT3000RM2UC
  • SMT3000RMT2U
  • SMX1000C
  • SMX1000US
  • SMX1500RM2UC
  • SMX1500RM2UCNC
  • SMX1500RMNCUS
  • SMX1500RMUS
  • SMX2000LV
  • SMX2000LVNC
  • SMX2000LVNCUS
  • SMX2000LVUS
  • SMX2200HV
  • SMX2200HVNC
  • SMX2200R2HVNC
  • SMX2200RMHV2U
  • SMX2200RMLVUS
  • SMX3000HV
  • SMX3000HV-BR
  • SMX3000HVNC
  • SMX3000HVT
  • SMX3000HVTUS
  • SMX3000LV
  • SMX3000LV2U-BR
  • SMX3000LVNC
  • SMX3000LVNCUS
  • SMX3000LVUS
  • SMX3000RMHV2U
  • SMX3000RMHV2UNC
  • SMX3000RMLVUS
  • SMX3KRMLVNCUS
  • SMX750C
  • SMX750CNC
  • SMX750-NMC
  • SMX750US
  • SRT1000RMXLA
  • SRT1000RMXLA-NC
  • SRT1000RMXLI
  • SRT10KRMXLI
  • SRT10RMXLIX806
  • SRT1500RMXLA
  • SRT1500RMXLA-NC
  • SRT5KRMXLT

https://www.dell.com/en-ca/shop/rack-pdu-2g-208v-24a-l21-30p-0u-vertical-rm-36xc13-6xc19-2x5-20/apd/a7284149/power-cooling-data-center-infrastructure#overview_section

Certifications & Standards
  • CSA C22.2 No. 60950
  • UL 60950-1
Environmental Compliance
  • Restriction of Hazardous Substances (RoHS)
  • Registration, Evaluation, Authorization and Restriction of Chemicals (REACH)
  • Battery Directive
Warranty1
Limited Warranty2 Year

Specifications are supplied by the manufacturer and subject to change. Contact a certified IT PRO at 1 (800) 235-4050 to confirm compatibility before ordering.