PRODUCT HIGHLIGHTS
- Product ConditionNew and Factory Fresh
- Limited Warranty2 Year
- Shipping Weight17 lbs.
- IEC 60320 C14
- 10 x IEC 60320 C13
- 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC
- 2.40 kVA
- Network (RJ-45)
- 1U/2U
- Horizontal Rackmount
Tripp Lite by Eaton PDU 2.4kW Single-Phase Switched Automatic Transfer Switch PDU Two 200-240V C14 Inlets 10 C13 Outputs 1U TAA
PRODUCT HIGHLIGHTS
- Product ConditionNew and Factory Fresh
- Limited Warranty2 Year
- Shipping Weight17 lbs.
- IEC 60320 C14
- 10 x IEC 60320 C13
- 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC
- 2.40 kVA
- Network (RJ-45)
- 1U/2U
- Horizontal Rackmount
Tripp Lite by Eaton PDU 2.4kW Single-Phase Switched Automatic Transfer Switch PDU Two 200-240V C14 Inlets 10 C13 Outputs 1U TAA
Overview
2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power RedundancyRecommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.Switches from Primary to Secondary Power Source in MillisecondsDynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership. Check Essential Functions at a GlanceA front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.Reduce Service Calls with Auto Probe Autonomous Device Management The Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).Easy to Install Horizontally in an EIA-Standard 19 in. RackThis ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.TAA-Compliant for GSA Schedule PurchasesThe PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. <a id=\"gfk-spex-minisite\" rel=\"nofollow\" href=\"javascript:void(0)\" onclick=\"javascript:window.open('//content.etilize.com/mini-site/en_us/1036679989.html','_b
OVERVIEW
Tripp Lite by Eaton PDU 2.4kW Single-Phase Switched Automatic Transfer Switch PDU Two 200-240V C14 Inlets 10 C13 Outputs 1U TAA

2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power RedundancyRecommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.Switches from Primary ...
PACKAGE CONTENTS
FEATURES & DESIGN
Key Specifications
| Plug/Connector Type | IEC 60320 C14 |
|---|---|
| Plug/Connector Detail | 2 x IEC 60320 C14 |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 10 x IEC 60320 C13 |
| Protection Type | Overload Protection |
Package contents
Accessories
- Tripp Lite by Eaton WEBCARDLX Network Card for Select UPS Systems and PDUs
- Tripp Lite by Eaton WEBCARDLX Network Card for Select UPS Systems and PDUs
- Tripp Lite by Eaton Water Leak Detection Sensor for Datacenter/Wiring Closet UPS/PDU
- Tripp Lite by Eaton EnviroSense2 (E2) Environmental Sensor Module Temperature
- Tripp Lite by Eaton SmartRack Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE TLNETEM E2MTHDI or E2MTDI
- Eaton Tripp Lite Series Computer Power Cord, NEMA L6-20P to C13 - Heavy-Duty, 15A, 250V, 14 AWG, 6 ft. (1.83 m), Black
- Tripp Lite by Eaton EnviroSense Rack Environment Sensor Temperature Humidity Contact-Closure Inputs
- Tripp Lite by Eaton EnviroSense2 (E2) Environmental Sensor Module with Temperature Humidity and Digital Inputs
Related Products
You may also like
- Server Technology PRO2 36-Outlets PDU
- Server Technology PRO2 36-Outlet PDU
- Eaton REPO Rack PDU
- Eaton ePDU T992 T9092B-CBSF 12-Outlets 3.33kW PDU
- Eaton ePDU TPC215 16-Outlets 4.99kW PDU
- Eaton RE 12-Outlets PDU
- Eaton ePDU 20-Outlets 4.99kW PDU
- Eaton Metered Input rack PDU, 0U, 309-460P9 input, 17.3 kW max, 200-240V, 48A, 6 ft cord, Three-phase, Outlets: (38) C13