PRODUCT HIGHLIGHTS
- Limited Warranty2 Year
- Shipping Weight0 lbs.
- 14U Rack-mountable
- AVR
- 6 Hour Recharge
- 4.30 Minute Stand-by
- 230 V AC Input
- 120 V AC, 208 V AC, 240 V AC Output
- 8 x IEC 60320 C19, 2 x NEMA L6-30R, 8 x NEMA 5-15/20R, 4 x NEMA 5-15R
- TAA Compliant
Tripp Lite by Eaton SmartOnline 120V 208/240V 20kVA On-Line UPS - Double Conversion, 18kW, N+1, 14U, Network Card Option, TAA Compliant
PRODUCT HIGHLIGHTS
- Limited Warranty2 Year
- Shipping Weight0 lbs.
- 14U Rack-mountable
- AVR
- 6 Hour Recharge
- 4.30 Minute Stand-by
- 230 V AC Input
- 120 V AC, 208 V AC, 240 V AC Output
- 8 x IEC 60320 C19, 2 x NEMA L6-30R, 8 x NEMA 5-15/20R, 4 x NEMA 5-15R
- TAA Compliant
Tripp Lite by Eaton SmartOnline 120V 208/240V 20kVA On-Line UPS - Double Conversion, 18kW, N+1, 14U, Network Card Option, TAA Compliant
Overview
Features Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss This N+1 UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring an 18,000W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline® SU20KRT-1TFTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment. It offers automatic N+1 redundancy at load levels up to 10kVA and non-redundant operation from 10kVA all the way up to 20kVA. Using the step-down transformer, the 20kVA UPS system can support both low- and high-voltage equipment. Reliable, Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The external battery provides 12.5 minutes of support at half load and 4.3 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the 20kVA UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite's field-replaceable, hot-swappable BP240V10RT3UTAA (sold separately). A battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries. Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed With its parallel PDU, the SU20KRT-1TFTAA with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring Front-panel LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status at a glance. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration. Optional WEBCARDLX Network Interface Offers 24/7 Access An accessory slot accommodates the optional Java-free HTML5-based WEBCARDLX interface, which enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card - install one card per included UPS power module) Advanced Communications Ports USB and DB9 ports (cables are included) enable data-saving unattended shutdown of connected systems when used with Tripp Lite's free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions.
OVERVIEW
Tripp Lite by Eaton SmartOnline 120V 208/240V 20kVA On-Line UPS - Double Conversion, 18kW, N+1, 14U, Network Card Option, TAA Compliant

Features Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss This N+1 UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring an 18,000W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline® SU20KRT-1TFTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment. It offers automatic N+1 redundancy at load levels up to 10kVA and non-redundant operation from 10kVA all the way up to 20kVA. Using the ...
PACKAGE CONTENTS
FEATURES & DESIGN
Key Specifications
| AVR | Yes |
|---|---|
| Plug/Connector Type | Hard Wire 3-wire (2PH + G) |
| Receptacle Type | IEC 60320 C19NEMA L6-30RNEMA 5-15/20RNEMA 5-15R |
| Receptacle Detail | 8 x IEC 60320 C192 x NEMA L6-30R8 x NEMA 5-15/20R4 x NEMA 5-15R |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
Package contents
Accessories
- Tripp Lite by Eaton WEBCARDLX Network Card for Select UPS Systems and PDUs
- Tripp Lite by Eaton UPS SNMP/Web/Modbus Management Accessory Card for compatible UPS Systems
- Tripp Lite by Eaton WEBCARDLX Network Card for Select UPS Systems and PDUs
- Eaton Tripp Lite Series 3 Relay I/O Mini-module
- Eaton Tripp Lite Series MODBUS Management Accessory Card for UPS Remote Monitoring and Control
- Tripp Lite by Eaton 2-Post Rack-Mount Installation Kit of 2U and Larger UPS Transformer and Battery Pack Components
- Tripp Lite by Eaton PDU 5.5kW Single-Phase Switched PDU - LX Interface 208/230V Outlets (16 C13) L6-30P Input 12 ft. (3.66 m) Cord 2U Rack-Mount TAA
- Tripp Lite by Eaton PDU 3.7kW Single-Phase Local Metered PDU 208/230V Outlets (6-C19 & 32-C13 ) C20/L6-20P Cable 10 ft. (3.05 m) Cord 0U Vertical