Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered PDU 200-240V Outlets (8 C19 and 40 C13) L6-30P 10 ft. (3.05 m) Cord 0U Vertical TAA 70 in.
PRODUCT HIGHLIGHTS
- Product ConditionNew and Factory Fresh
- Limited Warranty2 Year
- Shipping Weight17 lbs.
- NEMA L6-30P
- 8 x IEC 60320 C19, 40 x IEC 60320 C13
Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered PDU 200-240V Outlets (8 C19 and 40 C13) L6-30P 10 ft. (3.05 m) Cord 0U Vertical TAA 70 in.
Overview
The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers. Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2's all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facility's compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components' plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground. More from the Manufacturer
OVERVIEW
Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered PDU 200-240V Outlets (8 C19 and 40 C13) L6-30P 10 ft. (3.05 m) Cord 0U Vertical TAA 70 in.

The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers. Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded ...
PACKAGE CONTENTS
FEATURES & DESIGN
Key Specifications
| Plug/Connector Type | NEMA L6-30P |
|---|---|
| Receptacle Type | IEC 60320 C19IEC 60320 C13 |
| Receptacle Detail | 8 x IEC 60320 C1940 x IEC 60320 C13 |
| Protection Type | Overload Protection |
Package contents
Accessories
- Eaton Tripp Lite Series Heavy-Duty PDU Power Cord, C13 to C14 - 15A, 250V, 14 AWG, 2 ft. (0.61 m), Black
- Eaton Tripp Lite Series Heavy-Duty PDU Power Cord, C13 to C14 - 15A, 250V, 14 AWG, 10 ft. (3.05 m), Black
- Eaton Tripp Lite Series Heavy-Duty PDU Power Cord, C13 to C14 - 15A, 250V, 14 AWG, 6 ft. (1.83 m), Black
- Eaton Tripp Lite Series Power Cord, C19 to C14 - Heavy-Duty, 15A, 250V, 14 AWG, 4 ft. (1.22 m), Black
- Tripp Lite by Eaton Power Cord C19 to C14 - Heavy-Duty 15A 250V 14 AWG 6 ft. (1.83 m) Black
- Eaton Tripp Lite Series NEMA 5-15R to C14 Computer AC Power Cable - 13A, 125V, 16 AWG, 2 ft. (0.61 m), Black
- Tripp Lite by Eaton PDU 5.8kW Single-Phase Monitored Automatic Transfer Switch PDU 2 200-240V 30A L6-30P Inputs 1 L6-30R Outlet 1U
- Eaton Tripp Lite Series C20 to C13 Power Cord for Computer - Heavy-Duty, 15A, 100-250V, 14 AWG, 7 ft. (2.13 m), Black
You may also like
- Server Technology PRO2 36-Outlets PDU
- Server Technology PRO2 36-Outlet PDU
- Tripp Lite by Eaton 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (42 C13 & 12 C19), 0U Rack-Mount, Accessory for Select ATS PDUs
- Eaton fuse disconnect rack PDU, 0U, L22-30P input, 17.3 kW max, 230/400V, 24A, 10 ft cord, Three-phase, Outlets: (48) C13 Outlet grip, (12) C19 Outlet grip
- Eaton Metered Input rack PDU, 0U, 309-460P9 input, 17.3 kW max, 200-240V, 48A, 6 ft cord, Three-phase, Outlets: (48) C13, (12) C19
- Eaton Metered Input rack PDU, 0U, 309-460P9 input, 17.3 kW max, 200-240V, 48A, 6 ft cord, Three-phase, Outlets: (38) C13
- Eaton fuse disconnect rack PDU, 0U, 309-460P9 input, 17.3 kW max, 200-240V, 48A, 6 ft cord, Three-phase, Outlets: (48) C13 Outlet grip, (12) C19 Outlet grip
- Eaton fuse disconnect rack PDU, 0U, Hardwired input, 17.3 kW max, 230/400V, 24A, Hardwired, Three-phase, Outlets: (48) C13 Outlet grip, (12) C19 Outlet grip