Eaton Tripp Lite Series 12.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, CS8365C Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA

by
TRIPP LITE
PCN#
HH3878
MFG#
PDU3EVSR1H50
$2,204.72
cps

Extended & Accidental Damage Protection Plans Available Details

  Free Shipping
Estimated Shipment:

Calculating Shipping

Product Highlights:
  • Managed, Switched
  • Hubbel CS8365C 50A
  • 30 x IEC 60320 C13, 6 x IEC 60320 C19
  • Show more

Product Condition: New and Factory Fresh
Limited Warranty2 Year
Shipping Weight: 28 lbs.
Eaton Tripp Lite Series 12.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, CS8365C Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA
Tech Specs
Specifications

Manufacturer

Tripp Lite by Eaton

Manufacturer Part Number

PDU3EVSR1H50

Manufacturer Website Address

https://tripplite.eaton.com/

Brand Name

Tripp Lite by Eaton

Product Model

PDU3EVSR1H50

Product Name

PDU3EVSR1H50 36-Outlets PDU

Marketing Information

Features | 3-Phase Switched PDU Distributes, Monitors and Manages Network-Grade Power

Recommended for data centers, network service providers and large enterprises, this managed PDU with built-in network interface provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption, maintain proper load balance and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership.

36 Outlets Dispense AC Power to Connected Equipment

During normal operation, 36 individually controllable outlets-30 C13 and six C19-in three load banks distribute AC power to rack equipment. Each 200-240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load levels and load balancing.

IsoBreakerâ„¢ Technology Helps Maintain Critical Uptime During Overloads

Innovative IsoBreaker technology prevents the need to power down multiple devices when surges occur. In the event of a power surge due to an overload at an individual outlet, the load bank's circuit breaker trips only that outlet instead of the entire bank. This helps maintain uptime of servers and other critical equipment, avoiding a costly work stoppage.

Sophisticated Power Monitoring Includes THDv Waveform Capture

The THDv waveform capture feature is ideal for installations in which highly specific input voltage distortion measurements are critical, such as data centers, hospitals and airports. It identifies and captures the PDU input voltage quality by taking a 200ms waveform snapshot that triggers based on a THDv criteria. The THDv waveform capture trigger will capture 100ms before and 100ms after the trigger criteria. This helps provide precise input readings and accurately report line noise to help you diagnose power problems and avoid future downtime.

Built-In GbE-Capable Network Management Card Allows Remote Access 24/7

The built-in network interface with the latest version of PowerAlert® Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20's Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

Color Touchscreen LCD Offers Important Data at a Glance

An easy-to-navigate color touchscreen LCD reports a detailed analysis of PDU input/output data per phase, per bank and per outlet. It also provides information on energy consumption and peak power demand. It can generate a unique QR code to allow read-only access to the PDU via mobile device. If an EnviroSense2 module (sold separately) is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

Product Type

PDU
Technical Information

PDU Type

  • Managed
  • Switched

Phase

Three Phase

Plug/Connector Type

Hubbel CS8365C 50A

Receptacle Type

  • IEC 60320 C13
  • IEC 60320 C19

Receptacle Detail

  • 30 x IEC 60320 C13
  • 6 x IEC 60320 C19

Protection Type

  • Overload Protection
  • Circuit Breaker

Features

Multi-color LCD
Power Description

Input Voltage

230 V AC

Output Voltage Range

200 V AC - 240 V AC

Power Rating (Watt)

12.60 kW

Input Current

35 A
Management

Management

  • Network Card
  • PADM20
  • PAEM

Remote Outlet Switching

Yes
Physical Characteristics

Color Family

Black

Product Color

Black

Mounting Orientation

Vertical

Mount Type

Rack-mountable

Form Factor

Vertical

Rack Height

0U

Height

70"

Width

2.2"

Depth

3.1"

Weight (Approximate)

20.72 lb
Miscellaneous

Package Contents

  • PDU3EVSR1H50 36-Outlets PDU
  • Configuration Cable
  • Rack-Mounting Hardware
  • 2 x Spare Mounting Buttons
  • 2 x Toothed Washers
  • 2 x M4 Black Phillips Head Machine Screws
  • PDUMVROTATEBRKT Mounting Bracket Accessory
  • Owner's Manual

Application/Usage

  • Data Center
  • Server

Environmentally Friendly

Yes

Environmental Certification

RoHS

TAA Compliant

Yes
Warranty

Limited Warranty

2 Year